Arrayit Corporation Logo

Arrayit Corporation (ARYC) leads and empowers the genetic, research, pharmaceutical, and diagnostic communities through the discovery, development and manufacture of proprietary life science technologies and consumables for disease prevention, treatment and cure.  - Powerful Science for Life™

Products - Microarrayers - SpotBot® 2 Complete Desktop Personal Microarray Printers

325 installations worldwide make SpotBot® the world’s most popular personal microarray instrument.

Click here to watch our SpotBot® Movie!

Click here to watch our SpotBot® technical video.

Desktop-microarrayer
This revolutionary turnkey system allows microarray printing, processing and hybridizing right on your desktop. The SpotBot® 2 utilizes advanced micro-robotics to ensure accuracy, ease-of-operation and affordability. SpotBot® 2 will print 1,000 samples onto 14 substrates in duplicate in 6 hours using 4 of Arrayit’s patented Stealth or 946 Micro Spotting Pins. SpotBot® 2 is the perfect complement to any microarray core facility and the ideal personal microarrayer for the innovative researcher. The system includes substrates, printing solution, and a microarray wash station, centrifuge, and hybridization cassette.

Click on the arrow to view the SpotBot®  slideshow.


Click HERE to view the Standard SpoCLe Generator.
Click HERE to view the Multiple Microarray SpoCLe Generator.
Click HERE to view the Biacore SpoCLe Generator.
Click HERE to view the 96 & 384 Well Plate SpoCle Generator
NEW!! Humidity Control Apparatus for SpotBot 2.
NEW!! Megasonic Wash Station Upgrade!
Gal file generation help file: http://www.spotsupport.com/downloads/GALCreatorV1.0.02HELP.pdf

 SpotBot® 2 Complete Desktop System Features and Specifications:

  • SpotBot® 2 offers improved speed, precision and durability over SpotBot®
  • Includes extra hardware and consumables components (see below)
  • Axis resolution and repeatability of ±10 µm
  • Arrayit International’s patented printing technology (U.S. 6,101,946)
  • 4-pin printhead configuration (2 x 2 at 4.5 mm spacing)
  • Compatible with all Stealth and 946 Micro Spotting Pins
  • Holds 14 standard sized glass substrates (25 x 76 mm)
  • Holds one 384-well microplate
  • Printing routines allow 1-5 spots per sample
  • 3,600 spots per sub-microarray (9 x 9 mm)
  • 50,400 spots per entire substrate (18 x 63 mm)
  • Printing time of 2 hrs per 384-well microplate
  • >1,000 samples in 6 hours
  • Compatible with Windows XP, 2000, and NT 4.0
  • Power requirements: Standard 120 or 220 volt outlets
  • Ease-of-operation via new version 3 Graphical User Interface (GUI)
  • Size (H x L x W): 22 cm (8.7 in) x 30 cm (11.8 in) x 30 cm (11.8 in)
  • Weight: 6.4 Kg (14 lbs) including vacuum and peristaltic pumps

Unique Features of the SpotBot® 2 Complete Desktop System:

  • World’s only truly portable microarrayer (volume = 1.0 ft3).
  • World’s only turnkey microarray desktop manufacturing system.
  • Installation time < 60 minutes.
  • Arrives pre-calibrated from our laboratories in California.
  • Only system that uses micro-robotics for motion control.
  • “Zero” thermal emission, ultra-low energy consumption, and quiet operation.
  • Uses a forced air stream for pin drying, providing "zero" sample carry-over.
  • Super fast humidity control of 5% per minute and ±1 % at steady state.
  • Ultra-low wash buffer consumption of <1.0 liter per 8 hours of operation.
  • Ultra-low air turbulence minimizes sample evaporation during printing.
  • Ultra-low vibration improves printing quality and eliminates disruption of analytical balances, microscopes, scanners and other sensitive equipment.
  • Private label and OEM packages available to volume customers.
  • Only personal microarrayer in the world.

SpotBot® 2 Complete Desktop System Components:

SpotBot Papers:

Important Technical Note:
Your SpotBot® 2 Complete Personal Desktop Microarray System is calibrated in our laboratories in California to ensure proper Z-axis height over the substrates and platen, and correct pin placement in the wash and dry station, and 384-well microplate.  These calibration files are provided on a floppy disc in addition to the SpotSuite 3 installer CD. Calibration files are unique to your system and must be installed prior to operating your SpotBot® 2 system!!

microarray-circut-board
Figure 1.
SpotBot® 2 Complete Personal Desktop Microarray System printed circuit board. Shown is the printed circuit board and operation lights of the SpotBot® 2. Operation is computer-controlled and fully automated. The printhead shown in this photograph contains a calibration pin in the first of 4 pin apertures.

microarrayer-dry-pin
Figure 2. Shown is the wash and dry station of the
SpotBot® 2 Complete Personal Desktop Microarray System, with the wash port (left) and the drying port (right).  The printhead containing 4 Stealth Pins is fully inserted into the dry station in this photograph such that the collars rise above the top surface of the printhead by about 1.0 mm. Customers can also use 946 Pins with extended collars for ease-of-handling and greater printing precision.  A forced air stream generated by the SpotBot® 2 Air Compressor dries each pin independently, essentially eliminating sample carry-over. Cross-contamination can be further reduced further by using the Megasonic Wash Station option, a favorite of exacting users and those practicing protein microarray applications.

microarray-printer-plate
Figure 3.
Shown is theSpotBot® 2 Complete Personal Desktop Microarray System in the sample loading position. After the wash/dry step, the 4-pin Printhead moves over the first loading position in the 384-well microplate, lowers to the bottom of the plate, and pauses for 3 seconds allowing the samples load into the pin tips by capillary action. Each pin loads 0.2 µl of sample using the SMP4 or 946MP4 pin design. The recommended sample volume is 5-10 µl per well in a 384-well microplate. The SpotBot® 2 will print an entire 384-well plate across 14 substrates in less than 2 hours.

spotbot_2_microarray
Figure 4.
Microarray printed with dilutions of ArrayIt® Green540 and Red640 fluorescent dyes using the SpotBot® 2 Complete Personal Desktop Microarray System equipped with four 946MP4 Pins and a 946PH4 Printhead. All samples were printed in quintuplicate at 200-µm center-to-center spacing on SuperAmine Substrates.  The uniformity of the rows and columns of printed spots reveals the excellent printing performance of the SpotBot® 2.  The space bar denotes 500 µm in the image.

microarray-printer-slide
Figure 5.
Multiple microarrays per substrate printed with a SpotBot® 2 Personal Microarray Robot.  Shown is a photograph of the SpotBot® 2 platen containing SuperAmine Microarray Substrates printed with a SpotBot® 2 Personal Microarrayer running 946MP4 Pins printing at 175 µm spacing. A total of 24 microarrays per substrate were printed using the Multiple Microarray Format SpoCLe Generator version 1.1.02, which can be downloaded at http://myspotbot.com.

microarray-revolution
Figure 6. 
Multiple Microarray Format SpoCLe Generator version 1.1.02 allows the printing of multiple microarrays per substrate with SpotBot 2 Personal Microarrayers (see Fig. 5). Shown is a screenshot of the software interface. The user selects the number of microarrays or “well pattern”, spot spacing in microns, print offsets in millimeters, and subgrid dimensions as columns and rows.  The software then generates a graphic showing how the printed microarrays (orange icons) will appear on the substrates.  The Multiple Microarray Format SpoCLe Generator version 1.1.02 can be downloaded at http://myspotbot.com.

microarray-peristaltic
Figure 7.
Shown is a photograph of the Peristaltic Pump used on SpotBot®2 Personal Microarrayers. Tubing colors should be configured as shown. The speed dial should be set to the right (CW, clockwise setting) for correct buffer flow into the Wash Station.  Pumps are either 12 rpm or 100 rpm as designated on the back of the instrument under “speed”. A proper buffer flow rate of 1.0 ml/min into the SpotBot®2 Wash Station is achieved using dial setting 8 (12 rpm pump) or dial setting 1 (100 rpm pump, shown here).  Tubing connections (not shown) should be green-green, blue-blue, yellow-yellow, and white-white as designated on the tubing ends and hardware: green-green = Peristaltic Pump intake to Wash Buffer Reservoir; blue-blue = Peristaltic Pump intake to Wash Station outlet; white-white = Peristaltic Pump outlet to Wash Station intake; yellow-yellow = Peristaltic Pump outlet to Wash Waste Container.

microarray-spotters
Figure 8. Shown is a photograph of the SpotBot®2 Personal Microarrayer including the accessories. The translucent wash buffer reservoir, orange air compressor for the dry station, silver peristaltic pump for the wash station, silver megasonic power supply and humidification system including the orange air compressor, humidification reservoir and gray valve are shown correctly configured behind the instrument. The modular and compact accessories improve system utility and performance and simplify maintenance and repair. Inside the instrument, the microplate, L-bracket and temperature/humidity pen are visible.

microarrayer-spotting
Figure 9. Shown is a photograph of the SpotBot®2 Personal Microarrayer including the accessories. The translucent wash buffer reservoir, orange air compressor for the dry station, silver peristaltic pump for the wash station, silver megasonic power supply and humidification system including the orange air compressor and humidification reservoir are shown correctly configured behind the instrument. The COM cable, power supply, dry station fitting (red), wash buffer fitting (white), waste buffer outtake (blue), and humidification tubing are shown correctly attached to the back of the instrument. The modular and compact accessories design improves system utility and performance and simplifies maintenance and repair.

microarray-spotting
Figure 10. SpotBot®2 Microplate Printing. SpotBot®2 Complete Personal Microarrayers enable microarray printing into 96-well microplates (shown) and 384-well microplates, as well as onto microplate-sized glass substrates using the standard SpotBot®2 Complete components and Well Plate Printing Spocle Generator v2.0.2 software running on SpotApp v3.5.7. Microplate printing software is downloadable on the SpotSupport web site. Microplate printing requires the Microplate L-Bracket Locator (Cat. MLS) to hold the microplate in position during printing, and utilizes two pre-print substrates as shown here. System calibration is required prior to printing. Please do not attempt microplate printing prior to system calibration.

Ordering Information

Catalog ID

Description

Price (US dollars)*

SPA2XP

SpotBot® 2 Complete Personal Desktop Microarray System with version 3 software and intuitive graphical interface. Improved durability, precision, usability and performance compared to our original SpotBot®. Uses Arrayit’s patented printing technology (U.S. 6,101,946). Complete 22-component system brings microarray manufacturing to the desktop. The world’s only and best personal microarrayer just got better with SpotBot® 2.  Ideal for basic research and R&D, and a perfect complement to large microarrayers. System includes all of the components of the SPA2 as well as a Hybridization Cassette, Microarray High-Speed Centrifuge, and a Microarray High-Throughput Wash Station.

The new version of this product is SPA3XP

SPA2

SpotBot® 2 Personal Microarray System with version 3 software and intuitive graphical interface.  Improved durability, precision, usability and performance compared to our original SpotBot®.  Uses Arrayit’s patented printing technology (U.S. 6,101,946). Complete 22-component system brings microarray manufacturing to the desktop. The world’s only and best personal microarrayer just got better with SpotBot® 2. Ideal for basic research and R&D, and a perfect complement to large microarrayers.

The new version of this product is SPA3

UG2S

Software and hardware upgrade to convert your SpotBot® into a SpotBot® 2. Upgrade includes disassembly, cleaning, refurbishing, and extensive software and hardware upgrade for all SpotBot® Systems including SpotBot®, SpotBot® Complete, and SpotBot® Protein Edition.  The Upgrade restores and improves performance and extends SpotBot® longevity at a fraction of the cost of a new SpotBot® 2.

The new version of this product is UG3S

PWS

Complete one-year parts and service warranty for the SpotBot® 2 Personal Microarray System Complete. Warranty coverage includes all system components used in a regular manner except pins and printheads. Warranty does not cover system damage caused by irregular use.

$2,960

PWS2

Complete two-year parts and service warranty for the SpotBot® 2 Personal Microarray System Complete. Warranty coverage includes all system components used in a regular manner except pins and printheads. Warranty does not cover system damage caused by irregular use.

$4,914

PWS3

Complete three-year parts and service warranty for the SpotBot® 2 Personal Microarray System Complete. Warranty coverage includes all system components used in a regular manner except pins and printheads. Warranty does not cover system damage caused by irregular use.

$6,216

NWS

Non-warranty repair for all SpotBot® 2 Personal Microarrayers, including system inspection, testing, diagnosis, disassembly, parts, re-assembly, testing, calibration, cleaning, and printhead and wash station cleaning. Cost to replace platens, accessories and instrument cases may be higher. Please allow 3-6 weeks for non-warranty repairs.

$8,643

MSW110V

Megasonic Wash Station for SpotBot® 2 Personal Microarray Systems SPA2, SPA2XP, and SPA2PRO, 110 volt domestic version

$3,374

MSW220V

Megasonic Wash Station for SpotBot® 2 Personal Microarray Systems SPA2, SPA2XP, and SPA2PRO, 220 volt overseas version

$3,434

DSPA

Dehumidification Apparatus for all SpotBot® and SpotBot® PRO 1, 2 and 3 Personal Microarray Systems, reduces humidity from ambient to <10% RH ±1%, includes humidity control compressor, dessicator tube, control valve, air filter, hygrometer, and tubing, available in 110 volt and 220 volt systems.

$1,670

SPH4

4-Pin Stealth Printhead for SpotBot® 2 Personal Microarray Systems

$764

946PH4

4-Pin 946 Printhead for SpotBot® 2 Personal Microarray Systems

$800

ACS

Air Compressor for SpotBot® 2 Personal Microarray Systems

$1,137

PPS

Peristaltic Pump for SpotBot® 2 Personal Microarray Systems

$1,871

WDS

Wash and Dry Station for SpotBot® 2 Personal Microarray Systems

$1,510

SLS

Substrate Locator for SpotBot® 2 Personal Microarray Systems

$255

MLS

Microplate L-Bracket Locator to Position Microplates for Microplate Printing on SpotBot® 2 Personal Microarray Systems.

$330

CTS

Complete tubing set for SpotBot® 2 Personal Microarray Systems

$544

WBS

Wash Buffer for SpotBot® 2 Personal Microarray Systems, 1 liter of 1X solution, sterile and free of particulate and biological contaminants, ideal for all microarray wash stations including sonic systems, shipped pre-made and ready to use

$93

HFS

Humidity fitting for SpotBot® and SpotBot® 2 Personal Microarray Systems, 2 3/16” long with double 1/4” hose barbs, retainer nut and rubber humidity gasket. Connects to humidification and de-humidification options.

$89

AIC

Arrayit High-Performance Instrument Cleaner removes dust, particulates, fingerprints and other contaminants from SpotBot® 2 microarrayers. Apply using pump nozzle and Cleanroom Wipes, 65 ml of 1X solution.

$113

WBD

Wash Buffer Dispenser Bottle for SpotBot® 2 Personal Microarray Systems, 1 liter capacity

$153

WWC

Waste Wash Container for SpotBot® 2 Personal Microarray Systems, 1 liter capacity

$153

For the most current pricing information, technical assistance, and shipping schedules please contact us by email arrayit@arrayit.com, phone 408-744-1331, fax 408-744-1331, or click on the purchase buttons above to proceed directly to the product page.

*International pricing may vary as much as 30% (or more depending on country) due to import duties, stocking fees and technical support.

*Add shipping and handling to all orders.

 

Copyright 1993-2017 Arrayit Corporation. All rights reserved.