Products - Cleanroom Technology - Cleanroom Gloves
 

Synthetic nitrile, ultra-low particulate microarray cleanroom gloves for microarray cleanroom, pin and printhead handling, and other exacting microarray applications.

Table of Contents

Introduction
Congratulations on taking a big step towards improving the economies of scale, quality and speed of your microarray cleanroom research. This booklet contains a complete set of illustrations and protocols outlining the steps and principles needed to use ArrayIt® Microarray Cleanroom Gloves (MCGS, MCGM, MCGL, and MCGXL).

Quality Control
TeleChem assures the performance of this product.  The finest scientific research went into the development of this product.  Rigorous quality control monitoring on a lot-by-lot basis guarantees that these cleanroom gloves conform to the highest cleanroom industry standards.

Product Description
TeleChem's ArrayIt® Microarray Cleanroom Gloves (MCGS, MCGM, MCGL, and MCGXL) provide the highest quality synthetic nitrile cleanroom gloves at an affordable price, and are free of the latex proteins that can severely contaminate cleanrooms if normal latex gloves are used. All of our cleanroom gloves are packaged in state-of-the art class 100 cleanrooms, eliminating contamination of the gloves with particulates, proteases, nucleases and other contaminants that impair the quality of microarray experimentation if non-cleanroom gloves are used. Compare our cleanroom gloves with traditional laboratory gloves and you will see the difference.
Users will appreciate the following features of Microarray Cleanroom Gloves (MCGS, MCGM, MCGL, and MCGXL):

  • Packaged in state-of-the-art class 10 cleanrooms
  • Free of latex proteins and powder
  • Free of particulates, proteases and nucleases
  • Ultra-low emission of volatile and surface organics
  • Four sizes (small, medium, large, and extra large) to fit all cleanroom personnel
  • Convenient 100 gloves per package
  • High-tech synthetic nitrile composition
  • Ambidextrous for ease-of-use
  • Reinforced cuff for extra durability
  • Dimpled, sure-grip surface prevents drops and spills
  • Non-penetrating synthetic composition prevents liquid absorption
  • Use for handling substrates, pins, cassettes, and other microarray implements without transferring latex proteins
  • Compatible with all microarray cleanroom environments
  • Vast improvement over traditional laboratory and cleanroom gloves
  • Based on years of intensive microarray cleanroom R&D
  • Durable and chemically-resistant composition
  • No tearing with normal use
  • Affordable price of 90 cents per glove
  • 100 wipes per package
  • Anti-static packaging eliminates electrostatic contamination
  • Can also be used in traditional, non-cleanroom laboratories
  • Disposable
  • One year shelf life at room temperature

Technical Note
Federal Cleanroom Standard 209E defines and evaluates cleanrooms based on the number of particles of 0.5 µm diameter or larger present per cubic foot of cleanroom air, and those same standards are used to benchmark TeleChem’s microarray cleanrooms and cleanroom products.  Class 1, 10, 100, 1,000 and 10,000 cleanrooms contain fewer than 1, 10, 100, 1,000 and 10,000 particles/ft3, respectively.  ArrayIt® Microarray Cleanroom Gloves (MCGS, MCGM, MCGL, and MCGXL) are packaged in class 10 cleanrooms.  The ambient air in a traditional research laboratory contains up to 1,000,000 particles/ft3 depending upon the facility.

Figure 1. Microarray Cleanroom Glove (MCGS) in microarray handling and processing. Shown is a Microarray Cleanroom Glove (size small) being used to manipulate a bar-coded microarray substrate during microarray manufacture.  Optimal substrate handling requires gloves that are free of organic and particulate contaminants, and Microarray Cleanroom Gloves meet these important requirements.

Technical Assistance
Please contact us if you have any comments, suggestions, or if you need technical assistance.  By electronic mail: arrayit@arrayit.com (under the subject heading, please type, “Technical assistance”). By telephone: (408) 744-1331, Monday–Friday, PST 9:00am - 4:30pm. Please remember that we want to hear about your successes!
 

Figure 2.  Microarray Cleanroom Gloves for topical cleaning.  Shown are Microarray Cleanroom Gloves (MCGS), size small, being used to clean a stainless steel cart in a class 100 microarray cleanroom.  Cleanroom use requires routine cleaning or spill containment, and Microarray Cleanroom Gloves provide the hand protection needed for such tasks.

Short Protocol (Steps 1-6):
1. Remove the Microarray Cleanroom Gloves from the shipping box.
2. Decontaminate anti-static bag topically with 100% ethanol.
3. Decontaminate anti-static bag with particle-free forced air (optional).
4. Transport the Microarray Cleanroom Gloves into the cleanroom vestibule.
5. Transport the Microarray Cleanroom Gloves into the cleanroom.
6. Open the zip-lock package and use gloves as needed.

Complete Protocol (Steps 1-6):
1. Remove the Microarray Cleanroom Gloves from the shipping box. The packaging material is a silver-colored anti-static bag that prevents electrostatic and particle contamination of the gloves.  Do not open the anti-static bag until inside the vestibule or changing room of a cleanroom. Microarray Cleanroom Gloves also provide an excellent source of gloves for many non-cleanroom applications including the handling of microarray pins and printheads, microarrayers, scanners, microscopes, and other scientific instrumentation and equipment.  For non-cleanroom applications, open the anti-static package and use as needed.

2. Decontaminate anti-static bag topically with 100% ethanol.  Cover your hands with Microarray Cleanroom Gloves, wet a cleanroom wipe liberally with 100% ethanol, and wipe the outside of the silver anti-static package to remove particulates and other forms of debris.  Do not open zip-lock package until inside the cleanroom vestibule or changing room.

3. Decontaminate anti-static bag with particle-free forced air (optional). For Class 1, 10, 100 and 1,000 cleanrooms, the anti-static package should also be decontaminated with a filtered source of pressurized, oil-free air prior to entry into the cleanroom vestibule or changing room. Forced air removes additional contaminating particles prior to entering the cleanroom facility.  Make certain to wear Microarray Cleanroom Gloves at all times when handling the decontaminated, anti-static packaging material. Failure to wear suitable hand protection will introduce hand oils, ribonucleases, and other contaminants into the cleanroom.

4. Transport the Microarray Cleanroom Gloves into the cleanroom vestibule or changing area.  Make certain to remove shoes, sweaters, and other non-essential clothing prior to entering the cleanroom.  Microarray Cleanroom Gloves or equivalent hand coverings should also be worn at all times when inside a cleanroom. Step into a Microarray Cleanroom Suit, making sure that the appropriate cleansuit size (S, M, L, and XL) has been selected. Close the cleansuit by zippering the front completely, and make certain that the elastic wrist and ankle bands are positioned properly. Face shields and other respiratory devices can also be worn to provide additional containment against contamination.

5. Transport the Microarray Cleanroom Gloves into the cleanroom. Store the package gloves on an appropriate shelf or bench top away from heat sources until ready to use.

6. Open the zip-lock package and use gloves as needed. Place the opened zip-lock package on a benchtop or cleanroom shelf and use as needed to handle microarrayers, scanners, pins and printheads. Gloves should be worn at all times, and double gloves can be used in cases where frequent glove changes are required or for heavy tasks. Gloves should also be worn for hand protection when cleaning minor spills, and for topical cleaning of benches and other cleanroom surfaces. Microarray Cleanroom Gloves are disposable and soiled gloves can be discarded in the regular cleanroom waste containers.  The synthetic nitrile material should never be exposed to sources of open flame.

Recommended Equipment
Microarray Cleanroom Suits
Microarray Cleanroom Wipes
Stealth Micro Spotting Device
SpotBot® Personal Microarrayer
Super Microarray Substrates
High Throughput Wash Station
Microarray High-Speed Centrifuge
Microarray Hybridization Cassette

Troubleshooting Tips
Trouble donning gloves:

  • Hands contain moisture or perspiration.  Make sure hands are completely dry before donning gloves.  Use double gloves if frequent glove changes are required.

Tearing gloves exposes bare hands:

  • Use double gloves to prevent exposure of bare hands, and change outer glove layer as necessary during lifting or other heavy tasks.

Ordering Information

Product

Description

Number of gloves per package

Size

Catalog ID

Price per package (US dollars)*

Microarray cleanroom gloves

Synthetic nitrile with ultra-low particulates, packaged in class 10 cleanrooms

100

Small

MCGS

$99

Microarray cleanroom gloves

Synthetic nitrile with ultra-low particulates, packaged in class 10 cleanrooms

100

Medium

MCGM

$99

Microarray cleanroom gloves

Synthetic nitrile with ultra-low particulates, packaged in class 10 cleanrooms

100

Large

MCGL

$99

Microarray cleanroom gloves

Synthetic nitrile with ultra-low particulates, packaged in class 10 cleanrooms

100

Extra Large

MCGXL

$99

5-9 packages, 5% discount
10-19 packages, 10% discount
20-29 packages, 15% discount
30+ packages, 20% discount

To order ArrayIt® Brand Products: call 408-744-1331, fax 408-744-1711 or click on the button below to go directly to the purchase page.

*International pricing may vary as much as 30% (or more depending on country) due to import duties, stocking fees and technical support.

 

For a downloadable version of TeleChem’s protocols please click here.

International pricing may vary as much as 20% due to import duties, stocking fees and technical support.

*Plus shipping and handling.

Warranty
ArrayIt® brand products are developed and sold for research purposes only. ArrayIt® products are not for use in human diagnostics or for drug purposes, nor are they to be administered to humans in any way. Extreme care and exact attention should be practiced in the use of the materials described herein.  All ArrayIt brand products are subject to extensive quality control and are guaranteed to perform as described when used properly.
Any problems with any ArrayIt® brand product should be reported to TeleChem immediately.  TeleChem's liability is limited to the replacement of the product, or a full refund.  Any misuse of this product is the full responsibility of the user, and TeleChem makes no warranty or guarantee under such circumstances.

 

Copyright 1993-2008 TeleChem International, Inc. All rights reserved.