|
|
|||||||||||||||||||
|
Products - Buffers & Solutions - Hybridization Buffers - UniHyb Detect single base mismatches in any sequence! ArrayIt® has developed UniHyb Hybridization Solution for mutation detection, single nucleotide polymorphism (SNP) detection, DNA re-sequencing and sequencing by hybridization. UniHyb accelerates the rate of hybridization, reduces background and minimizes energetic differences between G-C and A-T base pairs, making UniHyb ideal for all microarray genotyping applications. 1.0 ml of 1.25X solution. Table of Contents Introduction Quality Control Product Description Users will appreciate the following features:
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
|
|
|||||||||||||||||||
![]() |
|||||||||||||||||||
|
Figure 1. Mutation detection. Shown are scanned images of oligonucleotide microarrays printed with TeleChem's ChipMaker 3 Micro Spotting device. Spacing is 150 µm center-to-center on silylated slides. The oligonucleotides are three pairs of amino-linked 15-mers bearing a perfect match (PM) or a single base mismatch (SM) relative to a Cy3-labeled probe. Hybridizations were performed for 4 hrs at 42°C with 0.2 pmole/µl probe in Unihyb Hybridization Solution (top) or 5X SSC + 0.2% SDS (bottom). Fluorescent detection was performed using the ScanArray 3000 from General Scanning, Inc. Improvements in hybridization signal and specificity are easily observed with Unihyb Hybridization Solution compared to a conventional hybridization buffer. Point mutations are easily identified in sequences spanning the entire range of AT and GC base composition. Technical Assistance Short Protocol (Steps 1-7) Complete Protocol (Steps 1-7) 2. Process the oligonucleotide microarrays for hybridization. After the oligonucleotides are spotted, the slides should be allowed to dry at room temperature overnight. This can be accomplished by placing the slides in a slide box with the lid slightly ajar. Drying increases the binding of the amino-modified oligonucleotide to the SuperAldehyde or SuperEpoxy surface. After drying, the slides should be processed to remove unbound oligonucleotide. Many protocols have been used for slide processing, though the one given below works well and is easy to implement. Transfer six slides to a TeleChem Wash Station and place the Wash Station and slides in a 600 ml beaker with a stir bar containing 500 ml of each buffer. Wash twice for 2 min each at room temperature in 0.2% SDS, twice for 2 min each at room temperature in dH20, once for 2 min at 95-100°C in dH20, cool to room temperature for 1 min, once for 5 min at room temperature in sodium borohydride solution (1.3 g NaBH4 dissolved in 375 ml phosphate buffered saline {PBS = Sigma Cell Culture Catalog # D8537}, then add 125 ml pure ethanol), three times for 1 min each at room temperature in 0.2% SDS, twice for 1 min each at room temperature in dH20. Air dry the slides to completion. Slides are ready for hybridization. 3. Resuspend the fluorescent probe in 1X UniHyb Hybridization Solution, which is provided as a 1.25X solution. This is accomplished by first resuspending the probe in 1.0 part dH20, then adding 4.0 parts of UniHyb Hybridization Solution. Do not attempt to re-suspend the probe in neat UniHyb. Prior to using UniHyb Hybridization Solution, pre-warm the solution for 30 sec at 65°C and mix by inverting the tube several times to re-dissolve the detergents present in the UniHyb. Failure to pre-warm the UniHyb prior to use may lead to poor hybridization results! A fluorescent probe desiccated to dryness would be re-suspended by adding 2.0 µl of dH20, followed by 8.0 µl of pre-warmed 1.25X UniHyb Hybridization Solution. Probes should be single-stranded DNA or RNA molecules made by either PCR or in vitro transcription of RNA. Probes containing polynucleotides 15-50 nt in length give superior hybridization results for mutation detection experiments compared to longer polynucleotides. 4. Hybridize the probe to the microarray under the appropriate conditions. This is accomplished by using 1.25 µl of probe in 1X UniHyb per cm2 glass cover slip. For best results, add the probe to one edge of the cover slip surface, then gently lower the cover slip onto the microarray with fine forceps allowing the probe to sheet evenly across the surface between the cover slip and the slide. Transfer the slide with cover slip to an ArrayIt® Hybridization Cassette containing 3.0 µl dH20, seal the cassette and hybridize for 0.5-4.0 hrs at the appropriate temperature. The hybridization temperature should be ~10°C below the Tm of the average heteroduplex on the microarray. TeleChem recommends the following hybridization temperatures with UniHyb Hybridization Solution: 15-mers (42°C), 17-mers (47°C), 19-mers (52°C), 21-mers (55°C), 23-mers (57°C), 25-mers (60°C). Shorter or longer oligonucleotides will utilize lower or higher temperatures, respectively. 5. Wash away the unbound fluorescent probe. Remove the microarray from the Hybridization Cassette and immediately transfer the slide to an ArrayIt Wash Station positioned in a 600 ml beaker containing 500 ml of 2X SSC + 0.2% SDS with constant mixing. After 1 min of mixing, gently remove the cover slip from the surface of the slide using a fine forceps. This can be accomplished by applying gentle pressure to the surface of the cover slip with the forceps, and sliding the cover slip off the surface of the microarray. Do not allow the forceps to contact the surface of the microarray directly. Direct contact can lead to scratches and poor data! Wash the slides once for 15 min at room temperature in 2X SSC + 0.2% SDS, then once for 5 min at room temperature in 2X SSC. Allow the slides to air dry for 15 min and blot off any remaining liquid. 6. Scan the microarray for fluorescent signals. Insert the 1" X 3" slide into the ScanArray 3000 (GSI Lumonics) or a compatible detection system and scan the area of the slide containing the microarray. The scan area, excitation source, laser power and PMT settings can all be adjusted with the ScanArray software. Laser and PMT settings should be chosen to give maximal unsaturated signal with minimal background fluorescence. Typically, laser and PMT settings of 70% and 60-80% respectively yield good results with the ScanArray 3000. 7. Score the hybridization results. Upload the scanned image tiff file into the ImaGene software (BioDiscovery) or a suitable quantitation package and examine each feature for fluorescence intensity. Oligonucleotides that form a perfect match (PM) with the fluorescent probe will produce greater fluorescence intensity than any of the single base mismatches (SM) oligonucleotides. The signal of the perfect match to a single base mismatch (SM) is 50:1-10:1 depending on the sequence. UniHyb References
Literature Cited de Saizieu, A., Certa, U., Warrington, J., Gray, C., Keck, W., and Mous, J. (1998) Bacterial transcript imaging by hybridization of total RNA to oligonucleotide arrays. Nature Biotech. 16: 45-48. Drmanac, S., Kita, D., Labat, I., Hauser, B., Schmidt, C., Burczak, J.D., Drmanac, R. (1998) Accurate sequencing by hybridization for DNA diagnostics and individual genomics. Nature Biotech. 16, 54-58. Hacia, J. G., Brody, L. C., Chee, M. S., Fodor, S. P. A., Collins, F. S. (1996) Detection of heterozygous mutations in BRCA1 using high density oligonucleotide arrays and two-colour fluorescence analysis. Nature Genet. 14: 441-447. Khrapko, K.R., Khorlin, A.A., Ivanov, I.B., Chernov, B.K., Lysov, Yu.P., Vasilenko, S.K., Florent’ev, V.L., Mirzabekov, A.D. (1991) Hybridization of DNA with oligonucleotides immobilized in gel: a convenient method for detecting single base substitutions. Molecular Biology 25: 581-591. Maskos, U., Southern, E.M. (1992) Oligonucleotide hybridizations on glass supports: a novel linker for oligonucleotide synthesis and hybridization properties of oligonucleotides synthesised in situ. Nucleic Acids Res. 20: 1679-1684. Vladimir Chizhikov, Avraham Rasooly, Konstantin Chumakov, and Dan D. Levy Microarray Analysis of Microbial Virulence Factors Appl. Envir. Microbiol. 2001 67: 3258-3263. Recommended Equipment and Reagents Troubleshooting Tips Ordering Information |
|||||||||||||||||||
|
|||||||||||||||||||
|
*International pricing may vary as much as 30% (or more depending on country) due to import duties, stocking fees and technical support. *To order ArrayIt® brand products: call 408-744-1331, fax 408-744-1711 or click on the Purchase button to proceed directly to the purchase page. Warranty
Copyright 1993-2008 TeleChem International, Inc. All rights reserved. |
|||||||||||||||||||